MODELL | 12V 400W | 15V 400W | 24V 400W | 36V 400W | 48V 400W | |
PRODUKTION | ANSPANNUNG WEITER | 12V | 15V | 24V | 36V | 48V |
COURANT NOMINAL | 33.3A | 26,6 A | 16.6A | 11A | 8.33A | |
GAMME ACTUELLE | 0 ~ 33.3A | 0 ~ 26,6A | 0 ~ 16.6A | 0 ~ 11A | 0 ~ 8.33A | |
PUISSANCE NOMINALE | 400W | 400W | 400W | 400W | 400W | |
ONDULATION UND BRUCH (MAX.) | 150 mVc-c | 150 mVc-c | 150 mVc-c | 150 mVc-c | 200mV | |
TOLÉRANCE DE SPANNUNG | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
KONFIGURATION, TEMPS DE MONTÉE | 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC ohne Aufladen | |||||
TEMPS D'ATTENTE (Typ.) | 20ms/230VAC 16ms/115VAC ohne Aufladen | |||||
BEITRAG | PLAGE DE SPANNUNG | 85~132 VAC/170~264 VAC | ||||
GAMME DE FRÉQUENZEN | 47 ~ 63Hz | |||||
FACTEUR DE PUISSANCE (typ.) | Leistungsfaktor > 0.6/220 VAC | |||||
WIRKSAMKEIT (typ.) | 75% | 78% | 80% | 83% | 84% | |
COURANT AC (typ.) | 7 A / 115 VAC 4 A / 230 VAC | |||||
COURANT D'APPEL (typ.) | 40 A / 115 VAC 60 A / 230 VAC | |||||
GERICHT-KREIS | Type de Protection: récupère automatiquement après la suppression de la condition de défaut | |||||
SCHUTZ | ZUSCHLAG | 105 ~ 135 % Modus hoquet, récupération automatique | ||||
DC ADJ. INTERVALL | 115 % ~ 135 % Bei Ausfall, automatische Rückgewinnung | |||||
UMWELT | TEMP DE TRAVAIL | -20 ℃ ~ + 60 ℃ | ||||
HUMIDITÉ DE TRAVAIL | 20% ~ 90% relative Luftfeuchtigkeit | |||||
LAGERTEMPERATUR, FEUCHTIGKEIT | -40 ℃ ~ + 85 ℃, 10 % ~ 90 % HF | |||||
SÉCURITÉ und CEM | LES NORMES DE SÉCURITÉ | CE, ROHS | ||||
SPANNUNG DE TENUE | I/PO/P: 1.5 KVAC I/P-FG: 1.5 KVAC O/P-FG: 0.5 KVAC | |||||
NORME DE TEST CEM | EN55015:2006;EN61547:1995+A1:2000;EN61000-3-2:2006; | |||||
EN61000-3-3:1995+A2:2005;EN61347-1:2001;EN61347-2-13:2006 |
Verständnis der Definitionen und Unterschiede von Geräten der Klassen I, II, III und 2
Im Bereich der Elektrik