MODELL | 12V 400W | 15V 400W | 24V 400W | 36V 400W | 48V 400W | |
WYNIK | NAPIĘCIE DC | 12V | 15V | 24V | 36V | 48V |
ZNAMIONOWY PRĄD | 33,3A | 26,6 A | 16.6A | 11A | 8.33A | |
ZAKRES PRĄDU | 0 ~ 33,3A | 0 ~ 26,6A | 0 ~ 16,6A | 0 ~ 11A | 0 ~ 8.33A | |
MOC ZNAMIONOVA | 400W | 400W | 400W | 400W | 400W | |
TŁUSZCZENIE I HAŁAS (MAKS.) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mV | |
TOLERANZ NAPIĘCIA | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |
KONFIGURACJA, CZAS WZROST | 1000 ms, 50 ms/230 VAC, 1000 ms, 50 ms/115 VAC auf Wunsch | |||||
CZAS PODTRZYMANIA (typ.) | 20 ms/230 VAC 16 ms/115 VAC für die Dauer der Messung | |||||
EINTRAG | ZAKRES NAPIĘCIA | 85~132 VAC/170~264 VAC | ||||
ZAKRES CZĘSTOTLIWOŚCI | 47 ~ 63Hz | |||||
WSPÓŁCZYNNIK MOCY (typ.) | Leistungsfaktor > 0,6/220 VAC | |||||
WYDAJNOŚĆ (typ.) | 75% | 78% | 80% | 83% | 84% | |
PRĄD AC (typ.) | 7 A / 115 VAC 4 A / 230 VAC | |||||
PRĄD ROZRUCHOWY (typ.) | 40 A / 115 VAC 60 A / 230 VAC | |||||
ZWARCIE | Typ Ochrony: samoczynnie przywraca się po usunięciu stanu awaryjnego | |||||
SICHERHEIT | PRZECIĄŻENIE | 105~135 % Testdauer, automatische Ausgabe | ||||
DC ADJ. ZASIĘG | 115 %~135 % Odcięcie wyjścia, automatyczne odzyskiwanie | |||||
ŚRODOWISKO | TEMPERATUR PRACY | -20℃~+60℃ | ||||
WILGOTNOŚĆ PRACY | 20 %~90 % wilgotności względnej | |||||
TEMPERATUR PRZECHOWYWANIA, WILGOTNOŚĆ | -40 ℃ ~ + 85 ℃, 10 %~90 % relative Luftfeuchtigkeit | |||||
BEZPIECZEŃSTWO i EMV | STANDARD BEZPIECZEŃSTWA | CE, ROHS | ||||
WYTRZYMAJ NAPIĘCIE | I/PO/P: 1,5 KVAC I/P-FG: 1,5 KVAC O/P-FG: 0,5 KVAC | |||||
STANDARDTESTÓW EMV | EN55015:2006;EN61547:1995+A1:2000;EN61000-3-2:2006; | |||||
EN61000-3-3:1995+A2:2005;EN61347-1:2001;EN61347-2-13:2006 |

Arten von Dimmern und ihre idealen Anwendungen
Universaldimmer U